ACO STORMBRIXX SYSTEM CONFIGURATIONS

There are multiple ways an ACO StormBrixx system can be configured. These designs depend on a number of factors including the size of system, site restrictions and the installation timetable.

Here are two typical ACO StormBrixx system configurations which utilise a mixture of installation techniques to provide a simple but strong and robust structure:

   
   
  Data Protection:
  Please tick the box if you
do not wish to receive related material
regarding our products
and services
 
  Name:
 
  Email:
 
 
PERIMETER RING LAYOUT

For this configuration only the perimeter of the system is brick bonded. The internal units are a series of single, double, treble, or quadruple units.

1. The installer should ensure that the footprint of the system is clearly marked out on the prepared and levelled base of the excavation. Lay geotextile and/or geomembrane.

2. The perimeter edge of the system should now be laid. Place two ACO StormBrixx tank pieces on the ground. Take a third tank piece, invert it and place it in a brick bonded method on top of the first two pieces. Continue laying bottom and top pieces alternately until a completely bonded outer ring is formed.

3. Assemble single to quadruple units. Place the units inside the perimeter ring to suit and connect to all other units using the ACO StormBrixx layer connector.

4. Repeat for subsequent layers using the connectors to bond layers to one another.

CONCENTRIC RING LAYOUT

This is a series of ever decreasing rings converging towards the centre of the system.

1. The installer should ensure that the footprint of the system is clearly marked out on the prepared and levelled base of the excavation. Lay geotextile and /or geomembrane.

2. The perimeter edge of the system should now be laid. Place two ACO StormBrixx tank pieces on the ground. Take a third tank piece, invert it and place it in a brick bonded method on top of the first two pieces. Continue laying bottom and top pieces alternately until a completely bonded outer ring is formed.

3. This installation method should then be repeated to create each internal ring. Each ring should be clipped to the outer ring using the ACO StormBrixx layer connector. See Multi layered cell configuration.

4. It may be necessary to cut a piece to complete the bond, particularly as you get towards the centre of the system.

5. Repeat for subsequent layers using the connectors to bond layers to one another.